December 13, 2011

Non-Invasive Blood Pressure in Mice and Rats

Over the past 20 years, explore scientists have attempted to non-invasively part mice and rat blood pressure (Bp) with varying degrees of success.
The quality to accurately and non-invasively part the systolic and diastolic blood pressure, in expanding to the heart pulse rate and other blood flow parameters in rodents, is of great clinical value to the researcher.

Invasive Blood Pressure, Rat and Mouse Measurement

"Pressure Transducer"

Direct blood pressure, an invasive surgical procedure, is the gold standard to compare the accuracy of non-invasive blood pressure (Nibp) technologies. Direct blood pressure should be obtained on the rodent's carotid artery when comparing to Nibp. "Validation in Awake Rats of a Tail Cuff formula for Measuring Systolic Pressure", Bunag, R.D., Journal of Applied Physiology, Vol 34, Pgs 279-282, 1973.

Radiotelemetry, a extremely invasive surgical procedure, is a very reliable blood pressure technology and is also utilized to compare the accuracy of Nibp technologies. Telemetry involves the implantation of radio transmitters in the rodent's body. This technique is well validated and has excellent correlation with direct blood pressure.

The benefit of implantable radio telemetry is the quality to continuously part rat and mouse blood pressure in free lively laboratory animals.

The disadvantages of radiotelemetry are: (1) morbidity connected with the initial surgical implantation of the transmitter; (2) morbidity connected with surgical operation required to replace the battery, which has a short battery life; (3) increase in the animal's level of stress, especially mice, in association to the large, heavy transmitters (2004, Atla, 4th World Congress, Einstein, Billing, Singh and Chin); (4) abnormal behavior since the animal cannot have social interaction due to the current technology requiring the implanted animal to be isolated, one animal per cage; (5) inability to perform high throughput screening; (6) high cost of the initial equipment set-up and the expensive transmitters that want frequent factory maintenance; (7) cost of material and human resources relating to ongoing surgeries; and (8) the lack of a competing market resulting in high stock and servicing costs.

Non-Invasive Blood Pressure, Rat and Mouse Measurement

The Nibp methodology consists of utilizing a tail cuff placed on the tail to occlude the blood flow. Upon deflation, one of any types of Nibp sensors, placed distal to the occlusion cuff, can be utilized to monitor the rat Bp. There are three (3) types of Nibp sensor technologies: photoplethysmography, piezoplethysmography and Volume Pressure Recording. Each formula will use an occlusion tail-cuff as part of the procedure.

1. Photoplethysmography

The first and oldest sensor type is Photoplethysmography (Ppg), a light-based technology. The purpose is to record the first appearance of the pulse while deflating the occlusion cuff or the disappearance of pulses upon inflation of the occlusion cuff. Photoplethysmography utilizes an incandescent or Led light source to record the pulse signal wave. As such, this light-based plethysmographic formula uses the light source to illuminate a small spot on the tail and attempts to record the pulse.

Photoplethysmography (Ppg) is relatively inaccurate since the readings are based solely on the amplitude of a particular pulse and can only imprecisely part the systolic blood pressure and the heart beat. There are many limitations to a light-based technology, such as: (1) over-saturation of the Bp signal by ambient light; (2) greatest sensitivity to the rodent's movement (motion artifact); and (3) the strangeness in obtaining enough mice blood pressure signals in dark skinned rodents (Pigmentation Differentiation). Light-based sensors also cause tail burns from close taste and prolonged exposure.

Diastolic blood pressure cannot be measured by photoplethysmography since the technology records only the first appearance of the pulse. If the diastolic Bp is displayed on the photoplethysmographic instrumentation, it is only an appraisal that is calculated by a software algorithm rather than a true measurement.

Additional variability and inaccuracy occurs in Ppg devices that rely on obtaining readings during occlusion cuff inflation.

Occlusion cuff distance is also an additional one source of variability and inaccuracy. Occlusion cuff distance is inversely connected to the accuracy of the blood pressure. Long cuffs, predominantly in most photoplethysmographic devices, record lower than the actual blood pressure measurements.

These limitations severely compromise the consistency, dependability and accuracy of the Nibp measurements obtained by devices that use light-based/Led photoplethysmographic technology.

The photoplethysmography formula correlates poorly with direct blood pressure measurements and is the least recommended sensor technology for Nibpe in rodents, especially mice.

2. Piezoplethysmography

The second Nibp sensor technology is piezoplethys-mography. Piezoplethysmography and photoplethysmography want the same first appearance of a pulse in the tail to record the systolic blood pressure and heart rate.

Both plethysmographic methods have similar clinical limitations. Whereas photoplethysmography uses a light source to attempt to record the pulse signal, piezoplethysmography utilizes piezoelectric ceramic crystals to do the same. From a technical point of view, piezoplethysmography is far more sensitive than photoplethysmography since the signal from the sensor is the rate of change of the pulse rather than just the pulse amplitude. Therefore, even extremely small mice with high velocity pulses will generate a enough signal to be detected with uncomplicated amplifiers.

Piezoelectric sensors are more spoton than light-based/Led sensors but the same plethysmographic limitations continue to yield inaccuracies in blood pressure measurements. On a positive note, the skin pigment of the rodent is not a measurement issue with piezoplethysmography as with photoplethysmography.

Although piezoplethysmography is good than photoplethysmography, both non-invasive tail-cuff blood pressure technologies compare poorly with direct blood pressure measurements.

3. Volume Pressure Recording

The third sensor technology is Volume Pressure Recording (Vpr). The Volume Pressure Recording sensor utilizes a specially designed differential pressure transducer to non-invasively part the blood volume in the tail. Volume Pressure Recording will nothing else but part six (6) blood pressure parameters simultaneously: systolic, diastolic, mean, heart pulse rate, tail blood volume and tail blood flow.

Since Volume Pressure Recording utilizes a volumetric formula to part the blood flow and blood volume in the tail, there are no measurement artifacts connected to ambient light; movement artifact is also greatly reduced. In addition, Volume Pressure Recording is not dependent on the animal's skin pigmentation. Dark-skinned animals have no negative corollary on Volume Pressure Recording measurements. Very small, 10-gram C57/Bl6 black mice are nothing else but measured by the Volume Pressure Recording method.

Special attentiveness is afforded to the distance of the occlusion cuff with Volume Pressure Recording in order to fetch the most spoton blood pressure readings.

Volume Pressure Recording is the most reliable, consistent and spoton formula to non-invasively part the blood pressure in mice as small as 10 grams to rats greater than 950 grams.

In an independent clinical validation study conducted in 2003 at Yale University, New Haven, Connecticut, Volume Pressure Recording correlated 99 percent with direct blood pressure:

"Volume Pressure Recording is excellent. It is very spoton and dependable. We performed experiments on temperature-controlled, adult rats and the non-invasive blood pressure measurements showed almost excellent correlation with invasive blood pressure measurements. We are very pleased with the results."

Numerous published explore papers are ready validating the accuracy, reliability and consistency of Volume Pressure Recording. See the Clinical Bibliography section.

Rodent Holders, Rat and Mouse

The ideal animal holder should favorably restrain the animal, generate a low-stress environment and allow the researcher to permanently recognize the animal's behavior. A trained rat or mouse can favorably and quietly remain in the holder for any hours.

It is very useful to integrate a darkened nose cone into the rodent holder to limit the animal's view and sacrifice the level of animal stress. The animal's nose will protrude straight through the front of the nose cone allowing for comfortable breathing. The tail of the animal should be fully extended and exit straight through the rear hatch opening of the holder.

The permissible size animal holder is critical for permissible blood pressure measurements. If the holder is too small for the animal, the minuscule lateral space will not allow the animal to breathe in a relaxed fashion. The animal will compensate by elongating its body, thereby creating a breathing artifact. A breathing artifact will cause immoderate tail appeal and undesirable blood pressure readings.

Animal Body Temperature, Rat and Mouse

A Nibp theory should be designed to favorably warm the animal, sacrifice the animal's stress and improve blood flow to the tail.

The rodent's core body climatic characteristic is very leading for spoton and consistent blood pressure measurements. The animal must have enough blood flow in the tail to fetch a blood pressure signal. Thermo-regulation is the formula by which the animal reduces its core body temperature, dissipates heat straight through its tail and generates tail blood flow.

Anesthetized animals may have a lower body climatic characteristic than awake animals so added care must be administered to sound the animal's permissible core body temperature. An infrared warming blanket or a re-circulating water pump with a warm water blanket is the adored formula to sound the animal's permissible core body temperature. The animal should be warm and comfortable but never hot. greatest care must be exercised to never overheat the animal.

Warming devices such as hot air heating chambers, heat lamps or heating platforms that apply direct heat to the animal's feet are not advisable to sound the animal's core body temperature. These heating devices will overheat the animal and increase the animal's respiratory rate, thereby expanding the animal's stress level. These conditions will elicit poor thermo-regulatory responses and generate inconsistent and inaccurate blood pressure readings.

Environmental Temperature

The permissible room climatic characteristic is critical for spoton blood pressure measurements. The room climatic characteristic should be at or above 26C. If the room climatic characteristic is too cool, such as below 22C, the animal will not thermo-regulate, tail blood flow will be reduced and it may be difficult to fetch blood pressure signals. A cold steel table or a colse to air conditioning duct are undesirable during animal testing.

Animal Preparation

The animal should be placed in the holder at least 10 to 15 minutes prior to obtaining pressure measurements. Acclimated animals will contribute faster Bp measurements than non-acclimated animals. permissible animal handling is critical to consistent and spoton blood pressure measurements. A nervous, stressed animal may have diminished circulation in the tail.

Most rodents will quickly adapt to new conditions and feel comfortable in small, dark and confined spaces. Training is not critical to fetch spoton blood pressure readings, however, some researchers prefer training sessions. Rodents can nothing else but be trained in almost three days, 15-minutes each day before starting your experiment.

The animal should be allowed to enter the holder freely. After the animal is in the holder, adjust the nose cone so the animal is comfortable but not able to move excessively. The animal should never have its head bent sideways or its body compressed against the back hatch. The animal's climatic characteristic should be monitored throughout the experiment.

Conclusion

Tail-cuff Nibp measurements can be consistent, spoton and reproducible when learning awake and anesthetized mice and rats. In addition, many animal testing is very cost-effective for large scale, high throughput screening. Care must be exercised to properly cope the animals. Training the animals and monitoring the animal's climatic characteristic may also be beneficial.

The volumetric pressure recording formula provides the highest degree of correlation with telemetry and direct blood pressure and is clearly the adored tail-cuff sensor technology.
Nibp devices that use Volume Pressure Recording are a critical tool in explore and will continue to be useful in many study protocols. The main advantages are: (1) they want no surgery; (2) they are significantly less expensive than other blood pressure equipment, such as telemetry; (3) they can screen for systolic and diastolic Bp changes over time in large numbers of animals; and (4) they contribute the researcher with the quality to fetch spoton and consistent blood pressure measurements over time in long-term studies.